LG Heat Pump Refrigerant Leak Inspection in Warwick, RI

November 12, 2026 — Evergreen Services
Heat pump Repair, Install & Replacement in Warwick, RI
Heat pump Repair, Install & Replacement
Heat pump Repair, Install & Replacement
Warwick, RI
ServiceHeat pump Repair, Install & Replacement
LocationWarwick, RI
Customer typeHomeowner
OutcomeCompleted — same day
Work performedRefrigerant leak diagnostic
DateNovember 12, 2026
Heat pump Repair, Install & Replacement Heat pump Repair, Install & Replacement Heat pump Repair, Install & Replacement Heat pump Repair, Install & Replacement Heat pump Repair, Install & Replacement Heat pump Repair, Install & Replacement Heat pump Repair, Install & Replacement Heat pump Repair, Install & Replacement Heat pump Repair, Install & Replacement Heat pump Repair, Install & Replacement Heat pump Repair, Install & Replacement
We inspected your LG multi-zone heat pump after concerns about low refrigerant levels and system performance. We found an audible refrigerant leak near the high-pressure sensor in the outdoor unit. The leak appears to come from the sensor or its connection, and further leak testing is needed to confirm the exact spot. Repair is recommended before further operation, but the repairs and refrigerant recharge have not yet been completed, and the replacement part and estimate are pending confirmation.
View technician’s notes

Refrigerant Leak Diagnostic

Equipment: LG Multi-Zone Heat Pump
Model: LMU300HHV
Refrigerant: R-410A
Suspected Component: High-Pressure Refrigerant Sensor
Part Number: EBD62165602 (pending model revision verification)

Diagnostic Summary:

Arrived on site to inspect the LG multi-zone heat pump system due to concerns regarding low refrigerant levels and system performance.

During the inspection, identified an audible refrigerant leak coming from the high-pressure sensor area located near the refrigerant accumulator inside the outdoor condenser unit.

The leak appears to originate from the pressure sensor or its connecting fitting. Further leak testing is required to confirm the exact failure point.

Recommended Repairs:

1. Recover the remaining R-410A refrigerant using approved recovery equipment.
2. Confirm the leak location and replace the high-pressure refrigerant sensor (Part # EBD62165602), if found defective.
3. Inspect the sensor connection and surrounding refrigerant piping for additional leaks.
4. Pressure-test the repaired system using dry nitrogen.
5. Evacuate the system to the manufacturer’s required vacuum level.
6. Recharge the system with R-410A refrigerant by weight according to LG specifications.
7. Test system operation, refrigerant pressures, and overall heating and cooling performance.

Repair Status:

Refrigerant leak identified in the pressure sensor area. Repair is recommended before further operation. System repairs and refrigerant recharge have not yet been completed. Replacement part and repair estimate pending confirmation.

Need Heat pump Repair, Install & Replacement in Warwick? Evergreen Services serves Warwick and the surrounding area. Licensed, insured, and locally experienced. Get a Free Estimate