DESCRIPTION:
Purchase and install one new 24K BTU Condenser located IN THE REAR RIGHT SIDE of the property
Purchase and install Three new 7K BTU heads. Locations to be determined by homeowner and technician.
OUTDOOR UNIT HAS TO BE INSTALLED 6’-8’ AWAY FROM ANY GAS OR ELETRICAL METERS OR LINES TO MEET LOCAL MECHNICAL CODE.
Purchase and install all necessary Fortress lineset cover, couplings, 90s, and terminations.
Install all necessary Line Set needed from Mini Split to newly installed outdoor heat pumps.
Purchase and install Communication Wire from outdoor unit to newly installed Evap Coil.
Install all necessary Condensate Piping from Indoor Fan Coil to outside unit.
Install all necessary copper piping and fittings to connect Line Set to newly installed condenser.
Fill and test Line-Set from indoor unit to outdoor and check for leaks using 450-500 PSI of Nitrogen (new mini split).
Purchase and install one new 10/2 wires from electrical panel to location of new Disconnect.
EPH is to install one new 220v electrical Disconnect for Mini Split.
Purchase and install one new 220v Whip for Mini Split.
EPH to run new 240V wire from electrical panel to Disconnect Box.
EPH to install new double pole breaker per manufacturer specifications
Evacuate all moisture from all equipment down to 500 Microns.
Turn on service valves and check refrigeration levels.
Add R-32 if needed.
All parts and labor to complete project is included in this price quote.