Called out for a slow leak under a bathroom vanity — traced it to a corroded shutoff valve on the cold supply line, the kind with the old compression-style fitting that tends to fail after 15-20 years. The valve body had developed a pinhole weep right at the packing nut, was dripping onto the cabinet floor. Swapped it out for a quarter-turn ball valve, soldered the connection clean, and tested under full pressure for about ten minutes with no weeping. Homeowner said the cabinet had smelled musty for weeks — now they know why.